Spot American Industrial Scientific
Compound multi-gas detector manufacturer supply price Industrial Scientific Huizhi Construction Professional recommends American Industrial Scientific
Gas Detector
Not just the most cutting-edge monitoring technology of Industrial Scientific An intelligent product, it is also the world's first composite gas monitor with a color LCD display and a variety of optional sensors.
The large-screen color display allows the instrument to read clearly in any brightness environment, such as low brightness or high brightness, which enhances safety. Whether in outdoor, indoor or underground working environments, potential gas hazards can be more easily discovered.
It can adopt diffusion and integrated pumping operation, which greatly facilitates remote measurement such as personal protection and confined space entry.
It is currently the most convenient instrument in the world to install various types of sensors. Whether electrochemical, catalytic combustion, infrared or sensors can be installed on the instrument at the same time, providing the most effective choice for users from all walks of life. In addition, the intuitive computer operation menu and five-way navigation key allow users to conveniently and intuitively perform instrument settings and function selections. Supports online charts to display instant readings and logged data. The large storage data recording and downloading functions provide users with comprehensive data browsing and processing functions. The casing is sturdy, enjoys a lifetime warranty, and is fully compatible with instrument management platforms and instrument networks.
Performance
Advantages
Color [prohibited word] LCD display
Use color [prohibited word] shape to clearly present information to user.
Menu-driven
Navigation is enabled through instrument capabilities (e.g. easy-to-understand graphical user interface). (Removable built-in GUI) operating system
Interchangeable/field-replaceable sensors
Provide flexible monitoring for a variety of applications. Reduce operating costs and downtime associated with instrument/sensor service. Including, infrared (, catalytic particles and electrochemical sensing functions)
Available to provide you with services at any time
Each instrument leaves the factory in a ready state, and users can easily connect the equipment and It is equipped with supporting equipment to implement services and run monitoring programs.
Multilingual Operation
Choose from pre-programmed language configurations, providing convenience and flexibility for multilingual and global workers.
Five-way instrument navigation button
Single button integrates up, down, left, right and confirmation functions to provide users with clearly identifiable tactile feedback when using the instrument's graphical menu options .
Diffusion or integrated sampling operations.
A single device for continuous monitoring in diffusion applications or with an integrated sampling pump for sampling operations such as confined space entry.
Power supply
A variety of power sources (including the latest battery charging technology) provide users with 24/7 performance monitoring, and battery power can be used with only a short notice in advance. Lithium-ion and alkaline batteries can be used interchangeably.
Incremental range lithium-ion battery pack
When using a sampling pump and or infrared sensor, it can achieve continuous hours of operation, and can extend the operation time in high power applications.
Numerical, graphical and text display modes
The instrument display can be personalized to provide gas concentration readings, a continuous graphical display of hazard trends, or just continue /Do not continue to facilitate user understanding.
Expanded Data Logging Memory
Onboard memory provides storage of gas readings at minute intervals for at least one year of operation.
Onboard event recorder
The most recent gas alarm event can be viewed on the instrument display, providing historical feedback information required for event review and evaluation.
The operating system is configurable by the user
The user can adjust the instrument for the specific display, alarm, calibration, data logging and other instrument operations required.
Impact test and self-test functions can be performed after startup
Users can choose to configure the instrument to perform self-test or impact test procedures during instrument startup to ensure that the instrument has been Test correctly.
Compatible with
Provides automatic calibration and record maintenance, reducing the total cost of instrument operation and ensuring correct documentation. Simplify training procedures and reduce the time and calibration gas required for each calibration operation.
Filled composite/stainless steel construction
Rugged construction provides the durability and immersion protection needed to operate in harsh industrial environments
.
Electronically enhanced RFI protection.
The enhanced design can protect workers and operating processes from radio frequency interference sources and eliminate false alarms and instrument failures.
Technical parameters
Housing material
Resin stainless steel with protective rubber padding
Dimensions
Diffusion version
Weight
General
Sensor principle
Combustible gas/methane catalytic combustion/infrared
Oxygen and toxic gas electrochemistry
Infrared
Volatile organic compound photoionization detector
Range
Gas
Chemical formula
Measuring range
Accuracy
Combustible gas
(Catalytic combustion )
Combustible gas (optional)
(infrared)
Methane
(catalytic combustion)
Methane (optional)
(Infrared)
Oxygen
/>
Carbon monoxide
Carbon monoxide (optional)
Hydrogen sulfide
Carbon monoxide/ Hydrogen sulfide**
Hydrogen
< br/>
Nitrogen oxide
Chlorine
Nitrogen dioxide
Sulfur dioxide
Hydrogen cyanide
< br/>
Ammonia
Dioxide Chlorine
Phosphine
Phosphine (optional)
Carbon dioxide
Volatile organic compounds (general)
**Two-in-one sensor
Display
/
Reading
Color [Prohibited Word] form
Operating temperature range
Normal
Operating humidity range
Normal ~, non-condensing (continuous )
Power Supply
/
Run Time
Rechargeable Li-ion Battery Case (Typical Hours)
Rechargeable Enhanced Type lithium-ion battery pack (normal operating time is hours)
Replaceable alkaline battery pack (normal operating time is hours)
Certification
Intrinsically safe
Equipment groups and classifications
Laboratory grade,,,, group
Canadian Standards Association grade,,,, group
U.S. Coal Mine Safety and Health Administration, Parts and Parts,
Safe for use in methane/air mixtures
Methane, Dioxide Chlorine carbon monoxide carbon dioxide hydrogen sulfide hydrogen cyanide hydrogen dioxide nitrogen monoxide ammonia oxygen phosphine volatile organic compounds, sulfur dioxide, benzene
American Industrial Scientific MX6 composite gas detector supply price